DeepCEST 3T: Robust MRI parameter determination and uncertainty quantification with neural networks—application to CEST imaging of the human brain at 3T
2019
Article
ps
Purpose: Calculation of sophisticated MR contrasts often requires complex mathematical modeling. Data evaluation is computationally expensive, vulnerable to artifacts, and often sensitive to fit algorithm parameters. In this work, we investigate whether neural networks can provide not only fast model fitting results, but also a quality metric for the predicted values, so called uncertainty quantification, investigated here in the context of multi-pool Lorentzian fitting of CEST MRI spectra at 3T. Methods: A deep feed-forward neural network including a probabilistic output layer allowing for uncertainty quantification was set up to take uncorrected CEST-spectra as input and predict 3T Lorentzian parameters of a 4-pool model (water, semisolid MT, amide CEST, NOE CEST), including the B0 inhomogeneity. Networks were trained on data from 3 subjects with and without data augmentation, and applied to untrained data from 1 additional subject and 1 brain tumor patient. Comparison to conventional Lorentzian fitting was performed on different perturbations of input data. Results: The deepCEST 3T networks provided fast and accurate predictions of all Lorentzian parameters and were robust to input perturbations because of noise or B0 artifacts. The uncertainty quantification detected fluctuations in input data by increase of the uncertainty intervals. The method generalized to unseen brain tumor patient CEST data. Conclusions: The deepCEST 3T neural network provides fast and robust estimation of CEST parameters, enabling online reconstruction of sophisticated CEST contrast images without the typical computational cost. Moreover, the uncertainty quantification indicates if the predictions are trustworthy, enabling confident interpretation of contrast changes.
Author(s): | Glang, Felix and Deshmane, Anagha and Prokudin, Sergey and Martin, Florian and Herz, Kai and Lindig, Tobias and Bender, Benjamin and Scheffler, Klaus and Zaiss, Moritz |
Journal: | Magnetic Resonance in Medicine |
Volume: | 84 |
Number (issue): | 1 |
Pages: | 450--466 |
Year: | 2019 |
Department(s): | Perceiving Systems |
Bibtex Type: | Article (article) |
Paper Type: | Journal |
DOI: | 10.1002/mrm.28117 |
Language: | eng |
State: | Published |
URL: | https://onlinelibrary.wiley.com/doi/10.1002/mrm.28117 |
BibTex @article{Glang2019deepcest, title = {{DeepCEST} {3T}: Robust {MRI} parameter determination and uncertainty quantification with neural networks—application to {CEST} imaging of the human brain at {3T}}, author = {Glang, Felix and Deshmane, Anagha and Prokudin, Sergey and Martin, Florian and Herz, Kai and Lindig, Tobias and Bender, Benjamin and Scheffler, Klaus and Zaiss, Moritz}, journal = {Magnetic Resonance in Medicine }, volume = {84}, number = {1}, pages = {450--466}, year = {2019}, doi = {10.1002/mrm.28117}, url = {https://onlinelibrary.wiley.com/doi/10.1002/mrm.28117} } |